Automated systems manufacturer required a non-helium leak test system for auto A/C connectors. Customer requirements included the ability to leak test multiple A/C connectors in parallel, and temperature cycling in leak test chambers. The customer also requested ability to configure leak testing for multiple refrigerants, and a method for calibrating the system

We engineered a custom, multi-chamber leak test system with remote mounting option for testing within temperature chamber.

  • Multi-chamber leak test system with PC-based control system
  • Design to allow remote mounting of test chamber in temperature chamber
  • Calibrated leak port to attach different refrigerant calibrated leaks for system calibration
Application:
Leak testing A/C parts
Industry:
Automotive A/C Systems & Components
Production Volume:
Medium to high
Tracer gas:
RGA refrigerant
Controller System:
Custom PLC
Leak Test Method:
RGA hard vacuum
Leak rate:
Dependent on refrigerant
Configuration:
Portable desktop station
Chamber:
Multiple custom tooled test fixtures


No accessories available.